Recording of communication from connected microphones at counters for customer service and at workplaces for control of technological and transport processes.
Recordings from ambient microphones can be used in addition to recordings of other technologies, such as telephone and radio communication lines, control terminal screens and other data sources. Records from ambient microphones help document and evaluate critical situations and thus contribute to increasing the safety and productivity of management processes.
Recording of communication from connected microphones at counters for customer service and at workplaces for control of technological and transport processes.
Technical parameters
ReDAT MIC-4CH Box is equipped with four XLR type connectors with the possibility of supplying a 48 V power supply for condenser type microphones (phantom power supply). So it records up to four microphones simultaneously. The recording mode is either permanent or switched when the set level of voice activity is reached. The extent of the recording space can be affected by a combination of the sensitivity/trigger level set in the microphone input channel and the directional characteristics of the microphone in use.
- A-Law 128 audio format (16 kHz sampling).
- Support for TCP / IP, SRTP protocols.
- Software equipment – firmware MIC-4CH is stored on a micro SD card. The complete configuration of the box is also stored on the micro SD card. The ReDAT MIC- 4CH Box is not equipped with any other non-volatile memory. Firmware update, event. configuration change is possible by simply replacing the micro SD card.
- Inputs 4x microphone – XLR connector, optional phantom power 48V.
- Dimensions (H x W x D) 45 x 130 x 130 mm.
- Weight 0.7 kg.
- IPv6 support.
- PoE power supply according to IEEE 802.3af / 802.3at (48 V). Max current consumption 200 mA. Power consumption: max 10 W, typically 6.5 W.
- Operating temperature 0 ° C to + 40 ° C.
- Storage temperature -10 ° C to + 60 ° C.
- Optical indication of the unit status (MIC-4CH box) by means of LED diodes.
- Status diagnostics via ReDAT eXperience (Monitoring, Audit):
- Monitoring the load of the recording channel, including the status of channel disconnection.
- Possibility of live listening and listening from the recording.